| 1 | Outdoor AC Rotary Isolator | 230/400 V AC | 16–160 A | 2–4 | Outdoor air-conditioning units, pumps, fans, and small machinery | IP65–IP66 polycarbonate or metal enclosure | Choose a load-break-rated model with a lockable handle and adequate motor-switching category. |
| 2 | Outdoor DC Solar Isolator | 600–1,500 V DC | 16–63 A | 2–4 | Photovoltaic string and inverter DC disconnection | IP65–IP66 UV-resistant enclosure | Use only a DC-rated switch; verify the voltage per pole, current, polarity, and PV utilization category. |
| 3 | Fused Outdoor Isolator Switch | 230/400 V AC; selected DC systems | 20–630 A | 2–4 | Outdoor feeders, distribution boards, transformers, and industrial equipment | IP54–IP66 metal or insulated enclosure | Match the fuse size, fuse class, short-circuit rating, and available space for heat dissipation. |
| 4 | Heavy-Duty Enclosed Isolator | 400–690 V AC | 63–630 A | 3–4 | Industrial motors, compressors, conveyors, and outdoor process equipment | IP65–IP66 metal enclosure | Check thermal derating, cable-gland size, fault withstand, and the required utilization category. |
| 5 | Pole-Mounted Medium-Voltage Isolator | 11–36 kV AC | 200–630 A | 3 | Overhead distribution lines, substations, and transformer isolation | Outdoor porcelain or polymer-insulated construction | Confirm insulation level, creepage distance, earthing arrangement, mechanical interlock, and local utility requirements. |
| 6 | Outdoor Load-Break Isolator | 230 V–36 kV AC | 16–1,250 A | 2–3 | Routine switching and isolation of energized low- or medium-voltage circuits | IP-rated low-voltage box or open-air MV assembly | Verify that the switch is rated to interrupt the intended load current; a plain isolator may not be opened under load. |
| 7 | Weatherproof Safety Isolator | 230/400 V AC | 20–100 A | 2–4 | Rooftop equipment, outdoor kitchens, gates, signs, and maintenance points | IP56–IP66 UV-stabilized enclosure | Select the IP rating according to rain, dust, washdown, sunlight, and impact exposure. |
| 8 | Motor-Rated Outdoor Isolator | 230/400/690 V AC | 16–250 A | 3–4 | Three-phase pumps, fans, compressors, and agricultural machinery | IP55–IP66 impact-resistant enclosure | Select the rating from the motor full-load current and confirm suitability for switching inductive loads. |
| 9 | Battery Energy Storage DC Isolator | 48–1,500 V DC | 63–630 A | 2–4 | Battery cabinets, inverters, telecom power, and microgrid systems | IP54–IP66 insulated or metal enclosure | Check DC breaking capacity, pre-charge requirements, polarity, arc control, and battery fault current. |
| 10 | Manual Transfer and Isolation Switch | 230/400 V AC | 40–630 A | 2–4 | Mains/generator changeover, standby power, and critical outdoor loads | IP54–IP66 enclosed switchgear | Use a mechanically interlocked, break-before-make arrangement unless a designed closed-transition system is required. |